Gold Member Since 2014
Ease Security Co., Ltd.

Touch Keypad, Remote Keyboard, Wireless Keypad manufacturer / supplier in China, offering Internal Antenna LCD Wireless Remote Touch Keypad Remote Keyboard, Emergency Manual Call Point for Fire Alarm (ES-9002), Photoelectric Wireless Smoke Detector for Fire Alarm Es-5001OSD and so on.

(/ )

Supplier Homepage Product GSM Alarm System Internal Antenna LCD Wireless Remote Touch Keypad Remote Keyboard

Internal Antenna LCD Wireless Remote Touch Keypad Remote Keyboard

Purchase Qty.:
(Pieces)
1-9,999 10,000+
FOB Unit Price: US $30 US $15
Purchase Qty. (Pieces) FOB Unit Price
1-9,999 US $30
10,000+ US $15
Get Latest Price
Production Capacity: 500 000 PCS/Month
Transport Package: Neutral Box
Payment Terms: L/C, T/T, D/P, Paypal, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: ES-2014K
  • Signal Transmission: Wired Alarm
  • Certification: SGS, ISO, RoHS, CCC
  • Sensor Type: Electric Alarm
  • Transmission Mode: Wireless
  • Receive Frequency: 433MHz or 868MHz
  • Dimension: 143*78*23 mm
  • Internal Antenna: Yes
  • Frequency: 433MHz or 868MHz Optional
  • Power: 12V
  • Specification: CE
  • HS Code: 8531901000
  • Type: Anti-Theft Alarm
  • Working Mode: Passive
  • Application: Indoor
  • Working Principle: Electromechanical
  • Alarm Volume (within 1m): ≥110dB
  • Usage: Door, Personal, Auto, Window, Fire, Smoke
  • LCD: Yes
  • Color: Black or White Optional
  • Password: 3 Grades
  • Trademark: Ease Security
  • Origin: China
Product Description
Internal Antenna LCD Wireless Remote Touch Keypad Remote Keyboard

Main Features
1. LCD screen with calendar function
2. Dual communication, display status of the alarm host
3. Compatible with the Wireless Alarm Host
4. Remote-control Arm/Disarm to the Alarm Host
5. Emergency alarm function
6. Operating voltage: 12VDC
7. Product dimension: 150*107*26(mm)

Function
1) Calendar function
2) It works with the alarm system, and can carry on the function of arm/disarm/emergency by password
3) It can receive the wireless signal from alarm system to show the status and prompt
4) One button programming, password recovery

Technical parameter
PowerDC12V
Power consumption<50MA
TransmitEncoding chipset: Single chip simulates ev1527, chipset code: 433 MHz, Timing resistor: 330K
ReceiveDecoding chipset: Single chip learning style; Frequency: 868 MHz Timing resistor: 330K

Working principle
It works with the alarm system, generally installs in the entrance, operates the keypad with password to control alarm system arming and disarming; And show the state of alarm system arming/disarming at real time. If we arming/disarming alarm system by the remote controller or the button of alarm system directly, the system will send the wireless signal to wireless keypad to show its synchronic state, if the system make alarm, the keypad will show the system is in alarm state, if the system disarmed, the keypads will also disarming.

Operating
1) Program menu setting: Press SET-(4 passwords)-ENT to the following menu setting:
Time setting: Press ENT, then put 6 numbers, 2 for" hour" 2 for"minite 2 for "second"
Date setting: Press ENT, then put 7 numbers, 2 for "year" 2 for "month" 2 for "date" 1 for "week", number 0 express Sunday
Wireless study: Press ENT, to chose study/clean study or clean the transmit signal.
Transmit address code set: Press ENT then put 8 numbers (A0-A7), for example "22110022", 2 express low level, 1 express high level, and 0 express vacant code, after setting, press ESC out.
Change password
1) User password: This password used for arming and disarming the system.
How to change?
SET-9999-ENT-choose change the user password -ENT- put old 4 program password (8888) -ENT- put new password -ENT- put new password again-ENT, exit automatically.

2) Program password: This password used for setting time, date and wireless address code etc.
How to change?
SET-9999-ENT-choose change the program password-ENT-put old 4 password-ENT-put new password (8888)-ENT-put new password again-ENT, exit automatically.

Mark: If the users forget the program password, please press the button on back for 5 seconds, "BI. "Sound for a while, the program password will return to 8888

Study operating
A. Study the keypad to system: Set the system to study state (detailed settings please refer to the manual of system), arming or disarming the keypad for 2 times. The system indicates that study successfully.
B. Study the system to keypad: Set the menu of keypad to study state, arming or disarming the system for 2 times. The keypad indicates that study successfully.

1) At home: Arming at home, the light on.
2) Power/battery: 8s flash one time, if the battery is low, the light N. O.
3) Arming: Arming at home/arming away, the light on.
Function
1) Calendar function
2) It works with the alarm system, and can carry on the function of arm/disarm/emergency by password
3) It can receive the wireless signal from alarm system to show the status and prompt
4) One button programming, password recovery
Send your message to this supplier
Avatar
Ms. Elaine Chan
Export Manager
*From:
To: Ms. Elaine Chan
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now